• English

    Language

    • English
    • Русский
    • Deutsch
    • Français
    • Español
    • Português
    • Italian
    • Japanese
    • Chinese (Simplified)
    • Chinese (Traditional)
    • Albanian
    • Arabic
    • Azerbaijani
    • Irish
    • Estonian
    • Basque
    • Belarusian
    • Bulgarian
    • Icelandic
    • Polish
    • Bosnian
    • Persian
    • Afrikaans
    • Danish
    • Filipino
    • Uzbek
    • Ukrainian
    • Tajik
    • Slovenian
    • Kazakh
    • Georgian
    • Lithuanian
    Choose Currency: USDUSD
    Save Cancel
  • |
  • Currency:
    USDUSD EUREUR CNYCNY
  • Sign In
Your position: Home / Epidemic prevention materials

OLED/LED Pulse Oximeter Medical Equipment Home SPO2 PR Apparatus Saturation Meter Portable Finger Oximeter Heart Rate Monitor

MED000066
Price:
USD
$25.99
    Please select the information you wantX
Quantity:
-
+
(5000 available)
Shipping Cost:
to
Estimated Delivery Time:
Please select the country you want to ship from
  • Description
  • Reviews
Introduction
Choose from three different types:
ST5436-1 (LED digital display)
ST5436-2 (LED dot matrix display)
ST5436-3 (OLED HD energy saving)
Package Contents:
-1 x fingertip oximeter
-1 x Lanyard
-1 x blister lining
-1 x English user manual
-1 x color box
Monitoring parameter SpO2:
Oxygenated hemoglobin saturation (SpO2)
Patient type: suitable for all persons over 4 years old
Measuring range: 70-99%
Analysis: 1%
Accuracy: between 70%--99% ± 2%
Oximeter saturation: An important indicator of the oxygen status in the body. It is generally believed that the normal value of blood oxygen saturation should not be less than 94%, and below 94% is considered to be insufficient oxygen.
Heart rate Pulse repetition rate (PR) BPM:
bpm solution: 1
Accuracy: 1% or 1 bpm
Heart rate (Heart Rate): refers to the number of beats per minute of the heart. It means that the heart beats fast in a certain period of time. The same person has a slower heart rate during quietness or sleep, and a faster heart rate during exercise or emotional excitement!
Blood flow indication PI value:
Measuring range 0.2% -30% PI
Analysis: 1%
PI refers to the Perfusion Index (PI). The PI value reflects the pulsating blood flow, that is, the ability of blood flow perfusion. The greater the pulsating blood flow, the more pulsating components and the larger the PI value. Therefore, the measurement site (skin, nail, bone, etc.) and the patient's own blood perfusion (arterial blood flow) will affect the PI value. Since the sympathetic nerves affect heart rate and arterial blood pressure (affecting pulse arterial blood flow), the human nervous system or mental state also indirectly affects PI values. Therefore, the PI value will be different under different anesthesia states.
 Instructions:
1. Insert two AAA batteries according to the positive and negative signs in the battery compartment and close the battery cover.
2. Pinch the finger clip pulse oximeter clip
3. Insert your finger into the rubber channel (finger should fully extend) and release the clip
4. Click the switch button on the front panel
5. Don't shake your fingers and the human body should not be in motion during use.
6. Read relevant data directly from the display, which can show blood oxygen saturation, pulse rate and pulse amplitude, PI perfusion index
Precautions:
1. Avoid exposure or direct sunlight
2. Avoid measuring during exercise, do not shake your fingers
3. Avoid extreme radiation of infrared or ultraviolet radiation
4. Avoid contact with organic solvents, mist, dust and corrosive gases
5. Avoid using near radio frequency transmitting devices or other electrical noise sources, such as: electronic surgical instruments, mobile phones, two-way wireless communication equipment for cars, electronic appliances, high-definition televisions, etc.
6, this instrument is not suitable for infants and newborns, only for children over 4 years old and adults.
7. The pulse rate waveform is normalized. When the pulse rate waveform tends to be smooth and stable, the measured value read is normal. At this time, the pulse rate waveform is also standard.
8. The tested person's fingers should be clean, and nails should not be applied with cosmetics such as nail polish.
9, fingers inserted into the rubber channel, the fingernails must be facing up, the same direction as the display
 
Average rating: 5.0
Share your thoughts with other customers
Write a review
About us
About Bizpal
Location and working hours
Terms and relations
General terms
Returns and replacement
Delivery policies
Privacy policy